2 posts / 0 new
Last post
tcrussell
Offline
Last seen: 5 years 3 months ago
Joined: 2014-08-11 16:02
VPP enable in production

AN-B-020 states that 6.8V can only be applied after VBAT and I see a provision to handle this on the Murata development board and a setting for it in SmartSnippets using an I/O pin to control VPP. What I don't see is any method for controlling the 6.8V separate from VBAT on the Dialog Basic or Pro boards. How is it handled in the Dialog development tools?

Device: 
MT_dialog
Offline
Last seen: 3 weeks 2 hours ago
Staff
Joined: 2015-06-08 11:34
Hi tcrussell,

Hi tcrussell,

In the basic and pro dk's you cant choose a pin in order to control the Vpp voltage. The choice for controlling is a feature for the expert dk. In the pro and basic dk's you just place the jumper in order to program the OTP.

Thanks MT_dialog